{"product_id":"sainsmart-rc200a-digital-temperature-microcomputer-intelligent-temperature-controller","title":"[discontinued] RC200A Digital Temperature Controller","description":"\u003ch5\u003eSPECIFICATION\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature range: temperature from minus 50\u003cspan\u003e℃\u003c\/span\u003eto 110\u003cspan\u003e℃\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eResolution: temperature 0.1\u003cspan\u003e℃\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eMeasurement accuracy:  ±0.1\u003cspan\u003e℃\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eControl precision:0.1℃\u003c\/li\u003e\n\u003cli\u003eFrequency refresh: 0.8 S\u003c\/li\u003e\n\u003cli\u003eInput  voltage:AC110-240V(chance)\u003c\/li\u003e\n\u003cli\u003eMeasuring input: DS18B20 Waterproof  type  sensor   \u003c\/li\u003e\n\u003cli\u003eOutput: relay 10A one channel\u003c\/li\u003e\n\u003cli\u003eEnvironments  requirement:temperature  from  minus   10\u003cspan\u003e℃\u003c\/span\u003e\u003cspan\u003e to 60℃\u003cspan\u003e, humidity from 20% to 85%\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eProduct size:144mm(long)*99mm(wide)*44mm(high)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003e\u003cspan\u003eINSTRUCTION\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003eStart lights: The equipment is Start to work when the Status light is light on.\u003cbr\u003eStop lights: The equipment is stop working when the Status light extinguish\u003cbr\u003eStatus indicator light will blink frequently and buzzer alarm when the measured temperature is greater than 110\u003cspan\u003e℃\u003c\/span\u003e or measured temperature is less than -50\u003cspan\u003e℃\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eButton instruction:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003eStart: set the temperature to start\u003cbr\u003eStop: set the temperature to stop\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSetting   instruction:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003e1.Refrigeration  Mode:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\nThe  refrigeration  equipment will start to work if the setting temperature of start is greater than stop and the testing temperature is greater than or equal to beginning. The refrigeration equipment will stop to work if the testing temperature less than or  equal to stoptemperature.\u003cbr\u003eFor example: Set the starting temperature is 20\u003cspan\u003e℃\u003c\/span\u003e, Stop temperature is 15\u003cspan\u003e℃. \u003c\/span\u003eRefrigeration equipment begins to work meanwhile the red indicator light  is  light when the detected temperature value is more than 20\u003cspan\u003e℃\u003c\/span\u003e. Refrigeration equipment stop working meanwhile the red indicator light extinguish when the detected temperature value is less than or equal to 15\u003cspan\u003e℃\u003c\/span\u003e.\u003cbr\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e 2. Heating  Mode :\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003eThe Heating equipment will start to work if the start temperature of set is less than  stop and the temperature of testing is small or equal to beginning. If the testing temperature greater than or equal to stop temperature, the Heating equipment will stop to work.\u003cbr\u003eFor example: Set the starting temperature is 15\u003cspan\u003e℃\u003c\/span\u003e, Stop temperature is 20\u003cspan\u003e℃\u003c\/span\u003e. Heating equipment start to work meanwhile the red indicator light is light. When the detected temperature value is less than or equal to 15\u003cspan\u003e℃\u003c\/span\u003e. Heating equipment stop to  work meanwhile the red indicator light extinguish. When the detected temperature value is more than 20\u003cspan\u003e℃\u003c\/span\u003e.  \u003cbr\u003e\u003cspan\u003e\u003cstrong\u003e3. Temperature correction mode:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003eThe system set temperature correction for positive and negative 9 degrees. The  temperature calibration can be carried out if feel the temperature measurement is  not accuracy or have a higher levels of thermometer.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperation method:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e1: Power off. 2: Hold down the Stop- button. 3: Power on.\u003cbr\u003eAt this time to enter the setting correction temperature and the \"measured temperature word\" sample disappeared, \"Measured temperature\" digital scintillation. Press \"Start+\" and \" Start-\" to adjust the correction temperature. The automatic return to normal state for 10 seconds and  the \"measured temperature\" appeared. Under normal condition showing the temperature be equal to measured temperature A plus correction temperature B.\u003cbr\u003eFor example: Correction temperature B = -0.5\u003cspan\u003e℃\u003c\/span\u003e, Actual measured temperature A= 25\u003cspan\u003e℃\u003c\/span\u003e, Then showing the  temperature  is  24.5\u003cspan\u003e℃\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"line-height: 1.4;\"\u003eIn the aspect of \u003cstrong\u003eraising pets\u003c\/strong\u003e, the product can be applied to fish tank, aquarium and crawler box etc.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"line-height: 1.4;\"\u003eIn  terms of \u003cstrong\u003efarming\u003c\/strong\u003e, the product can be applied to incubation and brood, temperature rise and keep  , ventilation and heat dissipation, temperature detection and warning etc.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"line-height: 1.4;\"\u003eIn \u003cstrong\u003eagriculture\u003c\/strong\u003e, the product can be applied to strain culture fermented, seedling culture, green house, cultivation and management of flowers and edible fungi etc.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"line-height: 1.4;\"\u003eIn the aspect of\u003cstrong\u003e intelligent home\u003c\/strong\u003e, the product can be applied to floor heating, water heating, heater,  electrothermal membrane, electrothermal bed, electric blanket and electric fan etc.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"line-height: 1.4;\"\u003eIn terms of \u003cstrong\u003efood\u003c\/strong\u003e, the product can be applied to make wine, fermented glutinous rice wine, flour fermentation , bean sprouts are cultivated , yogurt production, preservation of fruits and vegetables etc.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"line-height: 1.4;\"\u003eIn \u003cstrong\u003eindustry\u003c\/strong\u003e, the product is can be applied to temperature control cabinet, oven of experiment and warehouse monitor etc.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003e\n\u003cbr\u003eWHAT'S IN THE PACKAGE\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e1 x SainSmart RC200A Digital Temperature Controller Thermostat\u003c\/li\u003e\n\u003cli\u003e1 x English manual\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SainSmart","offers":[{"title":"US","offer_id":14669800734755,"sku":"101-70-172","price":26.17,"currency_code":"EUR","in_stock":false},{"title":"EU","offer_id":14669800767523,"sku":"101-70-173","price":26.17,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0029\/6838\/7619\/products\/101-70-172.jpg?v=1557256432","url":"https:\/\/de.sainsmart.com\/es\/products\/sainsmart-rc200a-digital-temperature-microcomputer-intelligent-temperature-controller","provider":"SainSmart Deutschland","version":"1.0","type":"link"}